3-22 FUEL SYSTEM (DFI)
Specifications
Item Standard
Oxygen Sensor:
Output Voltage (Rich) DC 0.7 V or more
Output Voltage (Lean) DC 0.2 V or less
Heater Resistance 11.7 ∼ 14.5 kΩ @20°C (68°F)
Immobilizer Antenna (Equipped Models):
Resistance About 3.0 ∼ 4.6 Ω
Purge Valve (Other than US, CA, ID and
SEA-B2 Models):
Resistance 30 ∼ 34 Ω @20°C (68°F)
Throttle Grip and Cables
Throttle Grip Free Play 2 ∼ 3 mm (0.08 ∼ 0.12 in.)
Air Cleaner
Air Cleaner Element Viscous paper element