3-22 FUEL SYSTEM (DFI)
Specifications

                  Item                                         Standard
 Oxygen Sensor:
    Output Voltage (Rich)                 DC 0.7 V or more
    Output Voltage (Lean)                 DC 0.2 V or less
    Heater Resistance                     11.7 ∼ 14.5 kΩ @20°C (68°F)
 Immobilizer Antenna (Equipped Models):
    Resistance                            About 3.0 ∼ 4.6 Ω
 Purge Valve (Other than US, CA, ID and
 SEA-B2 Models):
    Resistance                            30 ∼ 34 Ω @20°C (68°F)
Throttle Grip and Cables
 Throttle Grip Free Play                  2 ∼ 3 mm (0.08 ∼ 0.12 in.)
Air Cleaner
 Air Cleaner Element                      Viscous paper element